Warehouse robotics requirements, interfaces and acceptance evidenceOpen the RFQ checklist
RFQ / 01Load and flowInterfacesAcceptance
Compact requirements checklist

Ambi Robotics RFQ Data Sheet

Prepare the facts that allow a warehouse robotics concept to be evaluated consistently. Every target should name its unit, input source, revision, owner, operating condition and acceptance method.

Structured input table

Complete the boundary before comparing concepts

The table is an RFQ preparation aid, not a specification for a particular model. Unknown values can be entered as ranges and marked for confirmation.

Input groupRequired fieldUnit or formatWhy it changes the design
Load and geometryLoad envelope and carrierL × W × H in mmShapes pickup approach, station interface, turning and clearance.
Rated load and centerkg + center-of-gravity rangeChanges traction, stability, duty cycle and safe handling conditions.
Aisle and crossingsClear width in mm + scaled planDetermines route feasibility, passing rules and human interaction.
Floor and environmentSlope, joints, temperature, contaminantsDefines equipment limits, sensing conditions and maintenance exposure.
Demand and flowOrder or mission sampleTimestamped source fileReveals SKU depth, release pattern, travel and station demand.
Normal and peak targetUnits/hour or order lines/hourNeeds duration, mix, buffers, replenishment and backlog definition.
Operating calendarShifts/day, hours/shift, breaksInfluences duty cycle, charging opportunity and maintenance access.
Disruption scenariosTrigger, affected boundary, recovery objectiveTests resilience beyond a clean peak-throughput run.
Controls and acceptanceSystem responsibilityWMS / WCS / WES / fleet / PLC matrixPrevents overlapping ownership and unhandled state transitions.
Interface cycleCommand, acknowledgment and timeout in sConnects message behavior to physical material-flow timing.
Availability definition% + measurement window + exclusionsSeparates robot, zone, subsystem and end-to-end performance.
FAT / SAT evidenceScript, data revision, expected result, sign-offMakes acceptance repeatable and issues traceable into handover.
RFQ evidence checklist

Separate requirement references from proof documents

A standard name alone does not demonstrate conformity. Identify which requirement applies, which party owns the evidence and which product configuration the record covers. Company management-system certificates, machinery-design standards, regulatory conformity and third-party product certificates are different evidence classes.

The checklist below avoids assuming that Ambi Robotics or a particular model holds a certificate. Applicable documents must be reviewed for legal entity, issuing body, certificate or report number, scope, geography, revision and validity.

01

Risk and safety basis

Applicable risk assessment, operating modes, hazard controls, validation plan and residual-risk communication.

Possible references: ISO 12100, ISO 3691-4 and ISO 13849-1 where relevant.
02

Interface definition

Versioned message list, state model, timeout behavior, network assumptions and responsibility matrix.

Evidence: approved interface control document and emulation or integration record.
03

Performance method

Dataset, load mix, test duration, instrumentation, buffer state, exclusions and pass criteria.

Evidence: FAT/SAT script with observed result and traceable issue disposition.
04

Lifecycle readiness

Maintenance access, backup and restore, compatible spares, alarm triage, manual fallback and restart authority.

Evidence: handover index, training record and controlled recovery procedure.
Selection limits

Know what the RFQ cannot decide alone

These boundaries keep Ambi Robotics concept work honest. They are engineering limits for evaluation, not product claims for a named model series.

  • Rated load stated without center-of-gravity range and carrier mass is incomplete for AMR or AGV traction review.
  • Aisle / clear width in mm is meaningless without crossings, pedestrian interaction and safety laser scanner field assumptions.
  • System throughput in units/hour or order lines/hour requires SKU velocity, release pattern and buffer occupancy for the same window.
  • System availability % needs subsystem vs end-to-end measurement windows and explicit exclusions.
  • SLAM navigation suitability depends on floor quality, reflective surfaces, temperature and network assumptions that a rate target cannot replace.
Selection dimensions

Compare concepts on shared axes, not brand slogans

Use the same five axes for every option under review. Do not insert competitor names; score only the operating trade-offs that change capital, labor or recovery risk.

AxisExample unitTypical review question
System throughputorder lines/hour across a 4-hour peakWhat mix, backlog and replenishment assumptions sit behind the number?
Rated loadkg with load-center rangeDoes the carrier, tote or pallet change stability or duty cycle?
Aisle / clear widthmm on a scaled planWhere do robots, people and maintenance carts share space?
Controls boundaryWMS / WCS / WES / fleet / PLC matrixWho owns timeout, restart and inventory reconciliation?
Acceptance evidenceFAT script + 8-hour SAT windowWhich disruption cases must pass before handover?
RFQ next step

Submit the data revision, not a headline rate alone